你在這里
L Series Relays
?
?
LMMT
Multifunction
Dims: to DIN 43880
? ? ? ? W. 17.5mm
?
7 Selectable functions
7 Selectable time ranges (0.1 seconds一100 hours)
Fine adjustment of selected time range
Multi-voltage input (12一230V AC/DC +/-15%)
LED Warning indication if function is changed whilst powered
1 x SPDT relay output 8A
Green LED indication for supply / timing status
Red LED indication for relay status
Conforms to IEC 61812
?
?
?
LMMT/2
Multifunction
Dims: to DIN 43880
? ? ? ? W. 17.5mm
?
7 Selectable functions
7 Selectable time ranges (0.1 seconds一100 hours)
Fine adjustment of selected time range
Multi-voltage input (12一230V AC/DC +/-15%)
LED Warning indication if function is changed whilst powered
1 x DPDT relay output 8A
Green LED indication for supply / timing status
Red LED indication for relay status
Conforms to IEC 61812
?
LART
Asymmetrical Recycling
Dims: to DIN 43880
? ? ? ? W. 17.5mm
?
Recycling "On/Off" function AN ("Off / On" AF when external link fitted)
Separate adjustments for "on" and "off" ranges
7 Selectable time ranges (0.1 seconds一100 hours)
Fine adjustment of selected time range
Multi-voltage input (12一230V AC/DC +/-15%)
1 x SPDT relay output 8A
Green LED indication for supply / timing status
Red LED indication for relay status
Conforms to IEC 61812
?
LART/2
Delayed Pulse
Dims: to DIN 43880
? ? ? ? W. 17.5mm
?
Recycling "On/Off" function AN ("Off / On" AF when external link fitted)
Separate adjustments for "on" and "off" ranges
7 Selectable time ranges (0.1 seconds一100 hours)
Fine adjustment of selected time range
Multi-voltage input (12一230V AC/DC +/-15%)
1 x DPDT relay output 8A
Green LED indication for supply / timing status
Red LED indication for relay status
Conforms to IEC 61812
?
LEDO
Delay On Operate
Dims: to DIN 43880
? ? ? ? W. 17.5mm
?
Supply initiated, Delay On Operate timing function
7 Selectable time ranges (0.1 seconds一100 hours)
Fine adjustment of selected time range
Multi-voltage input (12一230V AC/DC +/-15%)
1 x SPDT relay output 8A
Green LED indication for supply / timing status
Red LED indication for relay status
Conforms to IEC 61812
?
LEIN
Internal
Dims: to DIN 43880
? ? ? ? W. 17.5mm
?
Supply initiated, Interval timing function
7 Selectable time ranges (0.1 seconds一100 hours)
Fine adjustment of selected time range
Multi-voltage input (12一230V AC/DC +/-15%)
1 x SPDT relay output 8A
Green LED indication for supply / timing status
Red LED indication for relay status
Conforms to IEC 61812
?
?
Switch Initiated Delav Off
Dims: to DIN 43880
? ? ? ? W. 17.5mm
?
Switch initiated (Constant supply), Delay Off timing function
7 Selectable time ranges (0.1 seconds一100 hours)
Fine adjustment of selected time range
Multi-voltage input (12一230V AC/DC +/-15%)
1 x SPDT relay output 8A
Green LED indication for supply / timing status
Red LED indication for relay status
Conforms to IEC 61812
?
LEDF
?Switch Initiated Delay Off??
Dims: to DIN 43880
? ? ? ? W. 17.5mm
True Delay Off timing function
Adjustment of time delay range
Dual-voltage input (24V AC/DC // 110V AC or 24V AC/DC // 230V AC)
1 x SPDT relay output 8A
Green LED indication for supply status
?
LEYD/A
True Delay Off
Dims: to DIN 43880
? ? ? ? W. 17.5mm
Star / Delta Start timing function
7 Selectable time ranges (0.1 seconds一100 hours)
Fine adjustment of selected time range
Selectable "Dwell" time (40·160ms)
Multi-voltage input (12一230V AC/DC +15/-10%)
1 x SPDT relay output 6A
Green LED indication for supply / timing status
Red LED indication for relay status
Conforms to IEC 61812
?
LEDK
Delay On Operate with Instantaneous Contact
Dims: to DIN 43880
? ? ? ? W. 17.5mm
Delay On Operate with Instantaneous Contact timing function
7 Selectable time ranges (0.1 seconds一100 hours)
Fine adjustment of selected time range
Multi-voltage input (12一230V AC/DC +15/-10%)
2 x SPDT relay outputs 8A
Green LED indication for supply / timing status
Red LED indication for relay status
Conforms to IEC 61812
?
LMAT
Multi-Attempt to Start
Dims: to DIN 43880
? ? ? ? W. 17.5mm
?
Multi-Attempt to Start timing function
Separate adjustments for "on" and "off" time ranges
7 Selectable "Start Attempts" (2·8)
Multi-voltage input (12一48V AC/DC +10/-30%)
2 x SPDT relay outputs 8A
Green LED indication for supply / timing status
Red LED indication for relay status
Conforms to IEC 61812
?
LMCCR-2A
Multifunction, Combined Current Monitoring
Dims: to DIN 43880
? ? ? ? W. 17.5mm
?
True R.M.S. monitoring
3 Selectable monitoring ranges (0.02一0.2, 0.1一1, 0.2·2A AC/DC)
Selectable Under or Over current monitoring
Selectable hysteresis, latch and power up delay options
Adjustable trip level and time delay
Isolated Auxiliary Supply 12一60V OR 24一230V AC/DC +15/-10%
1 x SPDT relay output 8A
Green LED indication for supply status
Red LED indication for relay status and Yellow for alarm
?
?
LMCCR-10A
Multifunction, Combined Current Monitoring
Dims: to DIN 43880
? ? ? ? W. 17.5mm
True R.M.S. monitoring
3 Selectable monitoring ranges (0.2一2, 0.5一5, 1一10A AC/DC)
Selectable Under or Over current monitoring
Selectable hysteresis, latch and power up delay options
Adjustable trip level and time delay
Isolated Auxiliary Supply 12一60V OR 24一230V AC/DC +15/-10%
1 x SPDT relay output 8A
Green LED indication for supply status
Red LED indication for relay status and Yellow for alarm
?
?
LBVR/A
Battery Voltage Monitoring
Dims: to DIN 43880
? ? ? ? W. 17.5mm
DC voltage monitoring
8一30V voltage range
Adjustable trip level
Adjustable time delay
1 x SPDT relay output 8A
Green LED indication for supply status
Red LED indication for relay status
?
LMCVR-20V
Multifunction, Combined Voltage Monitoring
Dims: to DIN 43880
? ? ? ? W. 17.5mm
True R.M.S. monitoring
5 Selectable monitoring ranges (0.1一1, 0.2·2, 0.5·5, 1·10, 2·20V
Selectable Under or Over voltage monitoring
Selectable hysteresis or latch option
Adjustable trip level and time delay
Isolated Auxiliary Supply 12一60V OR 24一230V AC/DC +15/-10%
1 x SPDT relay output 8A
Green LED indication for supply status
Red LED indication for relay status and Yellow for alarm
?
LMCVR-500V
Multifunction, Combined Voltage Monitoring
Dims: to DIN 43880
? ? ? ? W. 17.5mm
True R.M.S. monitoring
5 Selectable monitoring ranges (2一20, 5一50, 10一100, 20一200, 50一500V AC/DC)
Selectable Under or Over voltage monitoring
Selectable hysteresis or latch option
Adjustable trip level and time delay
Isolated Auxiliary Supply 12一60V OR 24一230V AC/DC +15/-10%
1 x SPDT relay output 8A
Green LED indication for supply status
Red LED indication for relay status and Yellow for alarm
Multifunction, Windowed Voltage Monitoring
?
Dims: to DIN 43880
? ? ? ? W. 17.5mm
True R.M.S. monitoring
7 Selectable Nominal voltage ranges (12一240V AC/DC)
Window operation Under and Over voltage monitoring
Adjustable Under and Over voltage trip levels
Adjustable time delay
Isolated Auxiliary Supply 12一60V OR 24一230V AC/DC +15/-10%
1 x SPDT relay output SA
Green LED indication for supply status
Red LED indication for relay status and Yellow for Under or Over voltage alarm
?
LXCVR
?
Under and Over Voltage
?
Dims: to DIN 43880
? ? ? ? W. 17.5mm
True R.M.S. monitoring
Monitors own supply
Adjustable Under and Over voltage trip levels
Adjustable time delay
1 x SPDT relay output 8A
Green LED indication for supply status
Red LED indication for relay status
?
LXPRC/S
Under & Over Voltage, Phase Loss+Sequence
?
Dims: to DIN 43880
? ? ? ? W. 17.5mm
True R.M.S. monitoring
Can be specified for 110, 208, 220, 380, 400 or 415V supplies
Monitors own supply and measures phase to phase voltages
Detects if one or more phases exceed the set Under or Over voltage trip levels
Detects incorrect phase sequence and phase loss
Adjustable Under and Over voltage trip levels
Adjustable time delay to prevent nuisance tripping
1 x SPDT relay output 8A
Green LED indication for supply and Red LED for relay statuses
?
LXPRC/S-4W
?
Under & Over Voltage, Phase & Neutral Loss+Sequence
Dims: to DIN 43880
? ? ? ? W. 17.5mm
?
True R.M.S. monitoring
Can be specified for 110, 208, 220, 380, 400 or 415V supplies
Monitors own supply and measures phase to neutral voltages
Detects if one or more phases exceed the set Under or Over voltage trip levels
Detects incorrect phase sequence, phase and neutral loss
Adjustable Under and Over voltage trip levels
Adjustable time delay to prevent nuisance tripping
1 x SPDT relay output 8A
Green LED indication for supply and Red LED for relay statuses
?
LXPRC
?
Under & Over Voltage+Phase Loss
Dims: to DIN 43880
? ? ? ? W. 17.5mm
True R.M.S. monitoring
Can be specified for 110, 208, 220, 380, 400 or 415V supplies
Monitors own supply and measures phase to phase voltages
Detects if one or more phases exceed the set Under or Over voltage trip levels
Detects phase loss and operates irrespective of phase sequence
Adjustable Under and Over voltage trip levels
Adjustable time delay to prevent nuisance tripping
1 x SPDT relay output 8A
Green LED indication for supply and Red LED for relay statuses
?
LXPRC-4W
Under & Over Voltage+Phase & Neutral Loss
Dims: to DIN 43880
? ? ? ? W. 17.5mm
True R.M.S. monitoring
Can be specified for 110, 208, 220, 380, 400 or 415V supplies
Monitors own supply and measures phase to neutral voltages
Detects if one or more phases exceed the set Under or Over voltage trip levels
Detects phase and neutral loss and operates irrespective of phase sequence
Adjustable Under and Over voltage trip levels
Adjustable time delay to prevent nuisance tripping
1 x SPDT relay output 8A
Green LED indication for supply and Red LED for relay statuses
?
LXPRT
Under Voltage, Phase Loss+Sequence
?
Dims: to DIN 43880
? ? ? ? W. 17.5mm
True R.M.S. monitoring
Can be specified for 110, 208, 220, 380, 400 or 415V supplies
Monitors own supply and measures phase to phase voltages
Detects an Under voltage condition on one or more phases
Detects incorrect phase sequence and phase loss
Adjustable Under voltage trip level
Adjustable time delay to prevent nuisance tripping
1 x SPDT relay output 8A
Green LED indication for supply status
Red LED indication for relay status
?
?
LXPRT-4W
Under Voltage, Phase &Neutral Loss+Sequence
Dims: to DIN 43880
? ? ? ? W. 17.5mm
True R.M.S. monitoring
Can be specified for 110, 208, 220, 380,
400 or 415V supplies
Monitors own supply and measures phase to neutral voltages
Detects an Under voltage condition on one or more phases
Detects incorrect phase sequence, phase and neutral loss
Adjustable Under voltage trip level
Adjustable time delay to prevent nuisance tripping
1 x SPDT relay output 8A
Green LED indication for supply status
Red LED indication for relay status
?
LXPRF
Phase Loss+Sequence
?
Dims: to DIN 43880
? ? ? ? W. 17.5mm
True R.M.S. monitoring
Can be specified for 110, 208, 220, 380,400 or 415V supplies
Monitors own supply and measures phase to phase voltages
Detects an Under voltage condition on one or more phases
Detects incorrect phase sequence and phase loss
Fixed Under voltage trip level
Fixed time delay
1 x SPDT relay output 8A
Green LED indication for supply status
?
?
LXPRF-4W.
?
?
Phase & Neutral Loss+Sequence
Dims: to DIN 43880
? ? ? ? W. 17.5mm
True R.M.S. monitoring
Can be specified for 110, 208, 220, 380, 400 or 415V supplies
Monitors own supply and measures phase to neutral voltages
Detects an Under voltage condition on one or more phases
Detects incorrect phase sequence, phase and neutral loss
Fixed Under voltage trip level
Fixed time delay
1 x SPDT relay output 8A
Green LED indication for supply status
Red LED indication for relay status
?
?
?
?
?
?